Fire & Evacuation

A 4565 • Emergency Alert & Evacuation Controller

This easy to operate fire & evacuation controller is designed around industry standard building emergency alert/evacuate requirements. When connected to a paging system amplifier, building occupants can be alerted and/or evacuated in the event of an emergency eg: fire, gas leak, bomb scare, earthquake.

A 4564 • Paging Console With Alert/Evac/Chime Control

A paging console for making announcements with the addition of alert/evac/chime functions. Ideal for emergency paging requirements to inform building occupants of current conditions.

A 4512 • 12A 24V Battery Charger Sealed Lead Acid (SLA)

Ideal for PA systems & other applications requiring battery backup. This all new model incorporates a highly efficient, intelligent, multi stage switchmode battery charger ensuring optimum battery charging and performance. 12A current output with 24V charging.

A 4506 • 6A 24V Battery Charger Sealed Lead Acid (SLA)

Ideal for PA systems & other applications requiring battery backup. This all new model incorporates a highly efficient, intelligent, multi stage switchmode battery charger ensuring optimum battery charging and performance. 6A current output with 24V charging.

A 4572 • Emergency Alert & Evacuation Tone Generator

This half rack unit has both Alert and Evacuation tones based on Australian standard AS1670.4. The unit is triggered via standard alert/evac switches on the front of the unit or via remote trigger contacts on the rear.

A 4567B • 10 Zone Line Monitoring Unit

Specifically designed to monitor the condition of 100V line speaker systems in emergency paging and fire evacuation installations. Traditional line monitoring units were limited to 50W per zone and would not handle this load. The A 4567B can handle loads up to 500W per zone.

A 4582 • 10 Zone Monitor Panel

A handy aid to test and adjust 100V line PA amplifier output levels. Capable of monitoring 10 individual amplifiers (electrically isolated from each other to prevent cross talk). Audible and visual monitoring is available from the built in speaker and VU meter.

A 4568 • Zone Status Interface To Suit A 4567B

Designed to interface the A 4567B Line monitoring unit with a fire indicator board. The addition of the A 4568 enables you to monitor the status of each individual zone.

A 4566 • In-Line 22uF Speaker line Isolator Box

This module has been designed to monitor the integrity of 100V Line speaker circuits. It is connected between the amplifier output and the speaker circuit. The module will detect one of three speaker line conditions. (Normal, Short Circuit or Open Circuit).

A 4500A • 50 Event 4 Output 24 Hour 7 Day Timer With Evac Tone Generator

A versatile timer which has four switched 24V outputs and four closing contacts which activate simultaneously. It permits a total of 50 event switching times.

A 4575B • Emergency Alert & Evacuation Controller

This easy to operate fire & evacuation controller is designed around industry standard building emergency alert/evacuate requirements. When connected to a paging system amplifier, building occupants can be alerted and/or evacuated in the event of an emergency eg: fire, gas leak, bomb scare, earthquake.

A 2070B • Tone Generator Alert/Evac With Voiceover Chip

Containing both the alert & evacuation tones based on Australian standard this compact self contained module will integrate with most PA amplifiers. Tones conform to AS1670.4.